Product details

AD80 Vertor Inverter for general purpose


The AD80 series general vector inverter adopts a book-style design with characteristics of compact size, electronics isolated from forced cooling air, simple structure, detachable control panel, and supporting wide range of applications.
Characteristic Specifications Size Download

Product Features

1、Plenty of Functions for General Purpose
With V/F and vector control;
Rich lO terminals and functions ;
Rich application functions, including process closed loop and multi-stage speed control etc.
2、Pluggable Keypad
Keypad hot-pluggable and can be remoted
Incremental potential meter.
3、Book Style Compact Size
Latest technology ofIGBT Chip with low switching power loss and high junction temperature rating.
Optimized in structure design and intelligent heat-temperature management to achieve the compact size and best power density.
Book style dimensions, supporting side-by-side mounting to save space in the cabinet.
4、High Reliability in Harsh Environment
Dust proof: fully sealed frame and electronics isolated from forced cooling air
Humidity proof: Coated PCBAs and specialized PCB layout and construction to counter humidity.
High temperature: Nominal load for 45°C ambient temperature, operation upto 60°C ambient.
Wide grid voltage range: 220V -15%~260V +10%,380V -15%~480V +10%
5、Easy to use
High motor control performance can be achieved without setting complex parameters.
Screw-free terminal for quick wiring

6、High performance cost ratio


Product Specifications

Number

Model

Description

1

AD80

On behalf of the inverter AD 80 series

2

4T

Represents the voltage level, 4T: three-phase 380V 2T: three-phase 220V 2S: single-phase 220V

3

1D5

Represents the power level, 1D5 represents 1.5kW 

 

AD80 product model specifications:

Model

Power(kW)

Voltage(V)

Input current(A)

Output current(A)

Air(m3/h)

AD80-2SD37

0.37

1×200-240

6.2

2.2

17.2

AD80-2SD75

0.75

1×200-240

9

4.2

17.2

AD80-2S1D5

1.5

1×200-240

15

6.8

17.2

AD80-2S2D2

2.2

1×200-240

22.5

9.2

17.2

AD80-4TD75

0.75

3×380-440

3.6

2.2

17.2

3×440-480

3.1

2.0

AD80-4T1D5

1.5

3×380-440

5.9

3.7

17.2

3×440-480

5.1

3.4

AD80-4T2D2

2.2

3×380-440

8.3

5.1

17.2

3×440-480

7.3

4.8

AD80-4T4D0

4.0

3×380-440

14.6

9.2

45.5

3×440-480

12.6

8.4

AD80-4T5D5

5.5

3×380-440

19.2

12.0

90

3×440-480

18.0

10.9

AD80-4T7D5

7.5

3×380-440

24.7

15.5

90

3×440-480

21.4

14.2

AD80-4T011

11

3×380-440

35.9

25

124

3×440-480

31.4

22.7

AD80-4T015

15

3×380-440

43.4

32

170

3×440-480

40.2

29.1

AD80-4T18D

18.5

3×380-440

51.5

38

230

3×440-480

46.1

34.5

AD80-4T022

22

3×380-440

61

45

272

3×440-480

54.5

40.9

AD80-4T030

30

3×380-440

82.5

61

303

3×440-480

74

52

AD80-4T037

37

3×380-440

115

73

374

3×440-480

103

65

AD80-4T045

45

3×380-440

133

88

408

3×440-480

120

79

AD80-4T055

55

3×380-440

150

105

476

3×440-480

142

97

AD80-4T075

75

3×380-440

200

145

595

3×440-480

180

130

AD80-4T090

90

3×380-440

233

172

646

3×440-480

210

155

AD80-4T110

110

3×380-440

273

204

714

3×440-480

245

187

AD80-4T132

132

3×380-440

320

250

850

3×440-480

288

225

AD80-4T160

160

3×380-440

375

302

1029

3×440-480

336

272

AD80-4T185

185

3×380-440

430

350

1190

3×440-480

388

315

 

Product Specifications:

Project

Specification

Input

Voltage

Single phase 200~240V - 15%~+10%

3-phase 380~480V - 15%~+10%

Frequency

50/60Hz ± 5%

Maximum unbalance degree

3%

Output

Output voltage

3-phase 0~100% output voltage

Output frequency

0~590Hz

Main control Specifications

Control mode

V/F, Vector control

Supported motor types

Asynchronous motor; synchronous motor

Starting torque

0.5Hz 150%

Overload capacity

150 % rated output current  (60s)  ; 180% rated output current  (3s)

Carrier frequency

0.37kW~7.5kW:2~12kHz;11kW~30kW:2~8kHz

37kW~110kW:2~6kHz;132kW~185kW:2~4kHz

Speed setting resolution

Digital: 0.001Hz, Analog: 0.5‰ of the maximum operating frequency

Open loop speed control accuracy

±0.5% rated

Control source of the command

Keypad,Communication,Digital input

Set frequency source

Keypad,Analog input, Communication

Acc / Dec

4 Groups Paraineter for Acc/Dec ; 0.05-60 00.00s

Basic function

Speed ​​open loop, process closed loop control , AMA,  automatic load compensation, DC compensation, acceleration and deceleration curve control, DC braking, AC braking, speed limit, current limit, fly start, etc. 

Application function

End-controlled multi-stage speed, programmable multi-stage speed, S ramp, mechanical brake, counter, process PID , point control and so on.

Protective function

Short circuit,ground fault,line phase loss,under voltage,over current,overload,over temperature motor thermal protection,motor phase loss,control wire broken etc.

Control terminal

  0.37~30kW 37kW~185kW
 Digital input 5DI,Select NPN or PNP by Jumper 5DI,Select NPN or PNP by Jumper
Analog input 2AI,Select 0~10V/0~20mA by Jumper 2AI,Select 0~10V/0~20mA by Parameter
Analog output1AO,Select voltage or current mode by jumper 2AO,Select voltage or current mode by jumper 
Relay output 1,Single pole double throw 2,Single pole double throw+Single pole double throw
Communication port1 RS4851 RS485
 Digital output 1DO of 40mA 1DO of 40mA
Output power supply 24V/50mA 24V/50mA
Analog Reference Power 10V/30mA 10V/30mA
Operation keyboard LED,Hot pluggable LED,Hot pluggable
External keyboard interface RJ45,Can be externally connected to KP00 RJ45,Can be externally connected to KP10
EnvironmentProtection gradeIP20
Working temperature

Operating range -10 °C ~ 55°C

45 ℃ rated load derate from 45 ℃ above

Working humidity5%-95% (no condensation at 95%)
Vibration≤110kW, 1.14g       ≥132kW, 0.7g 
Maximum altitude3000m, Derate for 1000m abve
Motor cable lengthShielded cable: 50 meters; Unshielded cable: 100m
OtherBraking unit

0.37-30kW built-in brake unit

37~110kW internal brake optional

Above 132kW without brake unit


Product Size

Power unit casing size table

Frame size

Power and voltage leve

Dimensions(mm)

 

1×200-240V

3×380-480V

W

H

D

W1

H1

d

S0

0.37-1.5kW

 

72

170

138

55

160

4.5

S1

2.2kW

0.75-4.0kW

82

185

163

65

175

4.5

S2

 

5.5-7.5kW

100

250

164

80

240

4.5

S3

 

11-18.5kW

155

330

189

130

315

6.5

S4

 

22kW

180

380

189

145

355

6.5

 

30kW

180

380

223

156

365

6.5

S5

 

37-55kW

 240

 490

 265

 180

 475

9

S6

 

75-110kW

 315

 660

 285

 200

 640

9

S7

 

132-185kW

 395

 800

 310

 280

 780

13

 


Message Consultation